Etc CEM3 v1.5.1 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Capteurs Etc CEM3 v1.5.1. ETC CEM3 v1.5.1 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 76
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Copyright © 2014 Electronic Theatre Controls, Inc.
All Rights reserved.
Product information and specifications subject to change.
Part Number:
7140M1200-1.5.1
Rev A
Released: 2014-06
CEM3
User Manual
Version 1.5.1
®
Vue de la page 0
1 2 3 4 5 6 ... 75 76

Résumé du contenu

Page 1 - User Manual

Copyright © 2014 Electronic Theatre Controls, Inc.All Rights reserved.Product information and specifications subject to change.Part Number: 7140M1200-

Page 2

4 CEM3 User Manual

Page 3 - Table of Contents

1 Getting Started 5Chapter 1Getting StartedThis chapter contains the following sections:• The User Interface . . . . . . . . . . . . . . . . . . . . .

Page 4 - Appendix C

6 CEM3 User ManualThe User InterfaceThis section will clarify the physical features of the hardware interface and the general functionality with the s

Page 5 - Appendix D

1 Getting Started 7Performing a Quick SetupQuick Setup is used to set up your rack using a minimum amount of data to achieve a basic configuration.You

Page 6

8 CEM3 User ManualOther Setup FunctionsOnce you have completed the quick setup, you may wish to proceed to these other common setup tasks:Setting the

Page 7 - Introduction

2 System Reference 9Chapter 2System ReferenceRefer to this chapter for information about the general concepts behind the features of your CEM3, the ge

Page 8 - Using this Manual

10 CEM3 User ManualImportant ConceptsThis section introduces you to some of the primary concepts and their functionality, which you may encounter thro

Page 9 - Asia Germany

2 System Reference 11CircuitA circuit is a user assignable number, between 1 and 99999. the circuit is the reference number for that dimmer in the rac

Page 10 - 4 CEM3 User Manual

12 CEM3 User ManualLatch-LockLatch Lock is a control mode available to any dimmer circuit (see Control:, page 20). Similar to switched mode, Latch-Loc

Page 11 - Getting Started

2 System Reference 13PatchPatching governs the relationship between control input sources (DMX A, DMX B, and sACN) and the control of circuits in the

Page 12 - The User Interface

ETC® and Sensor® are either registered trademarks or trademarks of Electronic Theatre Controls, Inc. in the United States and other countries.All othe

Page 13 - Performing a Quick Setup

14 CEM3 User ManualSystem TopologyEchoConnect - Belden 8471 + (1) 14 AWG ESD Ground WireEchoConnect - Belden 8471 + (1) 14 AWG ESD Ground WireExternal

Page 14 - Other Setup Functions

2 System Reference 15SpacesSpaces are logical divisions within a system (such as different rooms) that isolate station control (preset and sequence co

Page 15 - System Reference

16 CEM3 User ManualStraight (rack numbering)Straight rack numbering assigns consecutive dimmer numbering vertically, from top of the rack to the botto

Page 16 - Important Concepts

2 System Reference 17Menu StructureThis section lays out the entire menu structure for the software. Press the desired button to access the menu items

Page 17 - 2 System Reference 11

18 CEM3 User ManualSetupCommonly used features found here include:• changing dimmer, rack, and network settings• enabling control ports• changing oper

Page 18 - Latch-Lock

2 System Reference 19UI PreferencesAllows you to alter various settings regarding the user interface.Backlight ModeThis setting affects the backlight

Page 19 - Preset Functions

20 CEM3 User ManualFiring:The firing mode of the dimmer module. Options are: Normal, Dimmer Double, or Fluorescent. Specific module types will also of

Page 20 - System Topology

2 System Reference 21DMX A 16-Bit:Determines if the circuit receives 16-Bit data from DMX A. Yes/No (Default = No)DMX B The DMXB channel the circuit i

Page 21 - 2 System Reference 15

22 CEM3 User ManualRack Property DefinitionsEach rack has specific properties that dictate how the rack is identified and functions. When selected in

Page 22 - Straight (rack numbering)

2 System Reference 23Dimmer CurvesDimmer curves determine how dimmers set voltage output in response to control signal input. To accommodate designer

Page 23 - Menu Structure

Table of Contents iTable of ContentsIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . 1Using this Manual. . . . . . . . . . . . . . . .

Page 24 - 18 CEM3 User Manual

24 CEM3 User Manualthe same amount.0 20406080100020406080100Control Input (%)Dimmer Output (%)

Page 25 - Dimmer Property Definitions

2 System Reference 25Modified Linear (Mod-Linear)A modified linear curve reduces the voltage change at low control levels for better performance in lo

Page 26 - Dimmer Property Definition

26 CEM3 User ManualModified Square Law (Mod-Square)A standard square law curve may overcompensate for infrared loss, resulting in “steppy” response to

Page 27 - 2 System Reference 21

2 System Reference 27Stage 1This curve matches the stage curve of the Transtechnik PM90 dimming system.Stage 2This is a traditional German stage light

Page 28 - Rack Property Definitions

28 CEM3 User ManualFluor 1This curve is specifically for Nesys fluorescent devices.Fluor 2This curve is tuned to work with common 3-wire fluorescent b

Page 29 - Dimmer Curves

2 System Reference 29AndiThis curve is tuned to match the curve of Strand ANDI dimmer systems.VIP 90VIP90 is a curve specifically tuned to produce goo

Page 30 - Dimmer Output (%)

30 CEM3 User ManualDimmer Output DiagramThis diagram illustrates the relationship between min scale, max scale, curve, threshold, and preheat for the

Page 31 - Square Law (Square)

3 Common Tasks 31Chapter 3Common TasksThis chapter contains the following sections:• Recording and Playing Back Presets . . . . . . . . . . . . . . .

Page 32 - Sensor 2.0

32 CEM3 User ManualRecording and Playing Back PresetsCEM3 has the ability to record and play back snapshot looks called “Presets.”Presets can be recal

Page 33 - 2 System Reference 27

3 Common Tasks 33Saving or Uploading Files and FirmwareCEM3 allows you to save configurations to USB removable media, a computer connected to the netw

Page 34

ii CEM3 User ManualVIP 90 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29Dimmer Output Diagram . . . . . .

Page 35 - 2 System Reference 29

34 CEM3 User ManualLoading CEM3 SoftwareYou can upgrade your CEM3 software using the same methods as loading configurations (see above). CEM3 software

Page 36 - Dimmer Output Diagram

3 Common Tasks 35Setting Up PanicTo fully enable Panic functionality for your CEM3, the following criteria must be met:• a maintained contact closure

Page 37 - Common Tasks

36 CEM3 User Manual• Out Delay (sec) - This setting determines the length of time (in seconds) for the Panic look to delay before deactivating (defaul

Page 38 - Preset Menu

3 Common Tasks 37Setting Up PatchPatch governs the relationship between control sources (DMX A, DMX B, and sACN) and the rack’s circuits and is editab

Page 39 - Loading Configurations

38 CEM3 User ManualManual PatchManual patching allows you to alter the patch on a circuit-by-circuit basis. There are two independent options for manu

Page 40 - Loading CEM3 Software

3 Common Tasks 39the desired crossfade preset.d: Select “Preset Number” (Crossfade only) and select the desired preset (1-64) for the crossfade.Step 4

Page 41 - Setting Up Panic

40 CEM3 User Manualconfiguration it will be saved to the server. “No” means you will have to manually save.To manually save a configuration to an FTP

Page 42 - Panic Fade Diagram

3 Common Tasks 41DIP 2 - “AF”This switch should be set to “On” if your rack has Advanced Features (AF - see Advanced Features (AF), page 10).DIP 3 - “

Page 43 - Setting Up Patch

42 CEM3 User ManualRack Maintenance and CleaningProper air flow is necessary for your Sensor3 rack to function properly and consistently. Perform the

Page 44 - Set Data Loss Behavior

3 Common Tasks 43Step 5: Slide the top of the filter up into the slot at the top of the door until the base clears the metal retaining lip at the bott

Page 45 - Working with an FTP Server

iiiAppendix DFDX 3000 Dimmer Racks . . . . . . . . . . . . . . 55Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 46 - DIPswitch settings

44 CEM3 User ManualReplacing AF CardsAF cards are located on the right side of the dimmer module slot between the copper neutral busses and the dimmin

Page 47 - Termination Switches

3 Common Tasks 45Restore Rack DefaultsRestoring rack defaults is a fast way to completely reset all rack settings back to their original state. This f

Page 49 - Vacuuming Dimmer Modules

A Error Messages 47Appendix AError MessagesThe table below lists all of the possible error/status messages that may be listed on the CEM3 display foll

Page 50 - Replacing AF Cards

48 CEM3 User ManualRack Detect Error The CEM3 is unable to detect the rack type from the DIP switches on the backplaneCheck the CEM3 is seated correct

Page 51 - Restore Rack Defaults

B Using the CEM3 Web Interface 49Appendix BUsing the CEM3 Web InterfaceCEM3 features a basic web interface accessible over the system network using an

Page 52 - 46 CEM3 User Manual

50 CEM3 User ManualSet LevelsThis page allows you to set and release levels for any circuit in the rack.You can use the displayed keypad or a connecte

Page 53 - Error Messages

C Redundant Tracking Systems 51Appendix CRedundant Tracking SystemsCEM3 features the ability to support dual redundant controllers in ETC's ESR24

Page 54

52 CEM3 User ManualAutomatic ControlTypically, in a redundant tracking system, the switch should be left in the auto position. When the switch is set

Page 55 - Using the CEM3 Web Interface

C Redundant Tracking Systems 53The switchover from A to B for dimming happens instantaneously, so that control of lights is not lost. However, the swi

Page 56 - Set Levels

iv CEM3 User Manual

Page 58 - Display Status

D FDX 3000 Dimmer Racks 55Appendix DFDX 3000 Dimmer RacksCEM3 may be used as a control module in ETC's FDX3000 dimming system, providing networki

Page 59 - Redundant Tracking Systems 53

56 CEM3 User ManualRear PanelDimmer OutputsThe dimmer outputs connect from the FDX3000 processor to the dimmer module trays. They should generally be

Page 60 - 54 CEM3 User Manual

D FDX 3000 Dimmer Racks 57Regulatory InformationThe FDX3000 rack is certified to the following CE standards:Safety: EN61439-1 (Low voltage Switchgear

Page 61 - FDX 3000 Dimmer Racks

58 CEM3 User ManualAdvanced Features in FDXFDX3000 supports all module types available in the FDX series of racks, including the DP90 and DP90S series

Page 62 - Rear Panel

D FDX 3000 Dimmer Racks 59FDX2000 vs. FDX3000 Dimmer Curve ComparisonCurves in FDX3000 reference voltage rather than power. Therefore the following ta

Page 63 - 64 16 8 4 2 132

60 CEM3 User Manual

Page 64 - Advanced Features in FDX

61IndexAAbout menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17About CEM3 . . . . . . . . . . . . . . . . . . . . . . . . . 17dimmers .

Page 65 - D FDX 3000 Dimmer Racks 59

62 CEM3 User ManualMod-Linear . . . . . . . . . . . . . . . . . . . . . . . . . . 25Sensor 2.0 . . . . . . . . . . . . . . . . . . . . . . . . . . 26

Page 66 - 60 CEM3 User Manual

63Ffade timein presets . . . . . . . . . . . . . . . . . . . . . . . . . . . 32Fahrenheit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

Page 67

Introduction 1IntroductionWelcome to your new CEM3 Power Control system!This manual is designed to introduce you to the CEM3 user interface and the pr

Page 68 - 62 CEM3 User Manual

64 CEM3 User ManualOn-Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20PPanicdefinition . . . . . . . . . . . . . . . . . . . . .

Page 69

65restore defaults . . . . . . . . . . . . . . . . . . . . . . . . . . 45Rig check . . . . . . . . . . . . . . . . . . . . . . . . . . . 13, 17SsACNd

Page 70 - 64 CEM3 User Manual

66 CEM3 User ManualVVIP 90 curve . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29Voltage High Warnin rack properties . . . . . . . . . . . .

Page 74

Corporate Headquarters  3031 Pleasant View Road, P.O. Box 620979, Middleton, Wisconsin 53562-0979 USA  Tel +608 831 4116  Fax +608 836 1736London,

Page 75

2 CEM3 User ManualUsing this ManualThe following graphics and conventions are used throughout this manual to convey important information.Text Convent

Page 76

Introduction 3Help from ETC Technical ServicesIf you are having difficulties, your most convenient resources are the references given in this user man

Commentaires sur ces manuels